The scrub_address_max0_next register characteristics are:
- Usage constraints
Can be read from when in ALL states. Can be written to when in ALL states.
- Configurations
There is only one DMC configuration.
- Attributes
Offset | 0x178
|
Type | Read-write
|
Reset | 0x00000000
|
Width | 32
|
The following figure shows the bit assignments.
Figure 3-81 scrub_address_max0_next register bit assignments
The following shows the bit assignments.
- [31:0] scrub_address_max0_next
Program to set the ending address for the scrub engine. When scrub_addr_mode0 is set to physical_address this register specifies logical rank [24:22], physical bank [21:18] and physical row address [17:0] directly. When scrub_addr_mode0 is set to system_address this register specifies the address in the same address format used by incoming system transactions.