3.3.183 link_err_int_info_31_00

Shows information relating to the interrupt

The link_err_int_info_31_00 register characteristics are:
Usage constraints
Can be read from when in ALL states. Cannot be changed.
Configurations
There is only one DMC configuration.
Attributes
Offset
0x548
Type
Read-only
Reset
0x00000000
Width
32
The following figure shows the bit assignments.

The following shows the bit assignments.
[31:7] Reserved_1
Unused bits
[6] link_err_int_info_alert_n
Returns the value sent on the dfi_alert_n signal.
[5] link_err_int_info_err
Returns the value sent on the dfi_err signal.
[4:1] link_err_int_info
For a dfi_err error, returns the corresponding value sent on dfi_err_info. For all other errors it is not used.
[0] link_err_int_info_30_00_valid
Indicates if an overflow (single interrupt overflow, or multiple interrupt overflow) has occurred and whether the interrupt information is valid. One indicates it is valid and that no overflow has occurred.