3.3.201 timeout_control_now

Configures the prescaler applied to timeout values.

The timeout_control_now register characteristics are:
Usage constraints
Can be read from when in ALL states. Cannot be written to and only updated when in CONFIG, LOW-POWER or PAUSED states.
Configurations
There is only one DMC configuration.
Attributes
Offset
0x1048
Type
Read-only
Reset
0x00000001
Width
32
The following figure shows the bit assignments.
Figure 3-201 timeout_control_now register bit assignments
To view this graphic, your browser must support the SVG format. Either install a browser with native support, or install an appropriate plugin such as Adobe SVG Viewer.

The following shows the bit assignments.
[31:2] Reserved_1
Unused bits
[1:0] timeout_prescalar_now
timeout_prescalar_now bitfield.