3.3.209 access_address_min0_31_00_now

Configures the address space control for address region 0.

The access_address_min0_31_00_now register characteristics are:
Usage constraints
Can be read from when in ALL states. Cannot be written to and only updated when in CONFIG, LOW-POWER or PAUSED states.
Configurations
There is only one DMC configuration.
Attributes
Offset
0x1080
Type
Read-only
Reset
0x00000000
Width
32
The following figure shows the bit assignments.
Figure 3-209 access_address_min0_31_00_now register bit assignments
To view this graphic, your browser must support the SVG format. Either install a browser with native support, or install an appropriate plugin such as Adobe SVG Viewer.

The following shows the bit assignments.
[31:16] access_address_min0_31_16_now
Program to set bits[31:16] of the minimum address in the region
[15:4] Reserved_1
Unused bits
[3] region_s_write_en0_now
Enables Secure writes to the region
[2] region_s_read_en0_now
Enables Secure reads to the region
[1] region_ns_write_en0_now
Enables Non-secure writes to the region
[0] region_ns_read_en0_now
Enables Non-secure reads to the region
Non-ConfidentialPDF file icon PDF versionARM 100000_0001_00_en