3.3.264 scrub_address_max6_now

Configures the address space control for the scrub engine channel.

The scrub_address_max6_now register characteristics are:
Usage constraints
Can be read from when in ALL states. Cannot be written to and only updated when in CONFIG or LOW-POWER states.
Configurations
There is only one DMC configuration.
Attributes
Offset
0x11D8
Type
Read-only
Reset
0x00000000
Width
32
The following figure shows the bit assignments.
Figure 3-264 scrub_address_max6_now register bit assignments
To view this graphic, your browser must support the SVG format. Either install a browser with native support, or install an appropriate plugin such as Adobe SVG Viewer.

The following shows the bit assignments.
[31:0] scrub_address_max6_now
Program to set the ending address for the scrub engine. When scrub_addr_mode6 is set to physical_address this register specifies logical rank [24:22], physical bank [21:18] and physical row address [17:0] directly. When scrub_addr_mode6 is set to system_address this register specifies the address in the same address format used by incoming system transactions.