12.6.6 CTI Integration Test Trigger Out register

The CTIITTRIGOUT characteristics are:
Purpose
Provides direct observation of the trigger out signals.
Usage constraints
Accessible through the internal memory-mapped interface and the external debug interface. The access conditions are:
Off DLK OSLK EDAD SLK Default
- - - - WI WO
Table 12-3 Cross trigger register summary describes the access conditions.
Configurations
CTIITTRIGOUT is in the Debug power domain.
Attributes
See 12.5 Cross trigger register summary.
The following figure shows the CTIITTRIGOUT bit assignments.
Figure 12-7 CTIITTRIGOUT bit assignments
To view this graphic, your browser must support the SVG format. Either install a browser with native support, or install an appropriate plugin such as Adobe SVG Viewer.

The following table shows the CTIITTRIGOUT bit assignments.

Table 12-11 CTIITTRIGOUT bit assignments

Bits Name Function
[31:8] - Reserved, RES0.
[7:0] CTTRIGOUT Set the value of the CTTRIGOUT outputs.
Non-ConfidentialPDF file icon PDF versionARM 100095_0002_03_en