A.7 Power management signals

The processor has retention and non-retention signals for power management.

Table A-8 Non-Retention power management signals

Signal Direction Description
CLREXMONREQ Input

Clearing of the external global exclusive monitor request. When this signal is asserted, it acts as a WFE wake-up event to all the cores in the processor device.

CLREXMONACK Output

Clearing of the external global exclusive monitor acknowledge.

EVENTI Input Event input for processor wake-up from WFE state.
EVENTO Output Event output. Active when a SEV instruction is executed.
STANDBYWFI[CN:0] Output

Indicates whether a core is in WFI low-power state:

0Core not in WFI low-power state.
1Core in WFI low-power state. This is the reset condition.
STANDBYWFE[CN:0] Output

Indicates whether a core is in WFE low-power state:

0Core not in WFE low-power state.
1Core in WFE low-power state.
STANDBYWFIL2 Output

Indicates whether the L2 memory system is in WFI low-power state. This signal is active when the following conditions are met:

  • All cores are in WFI low-power state, held in reset, or nL2RESET is asserted LOW.
  • In an ACE configuration, ACINACTM is asserted HIGH.
  • In a CHI configuration, SINACT is asserted HIGH.
  • If ACP has been configured, AINACTS is asserted HIGH.
  • L2 memory system is idle.
L2FLUSHREQ Input L2 hardware flush request.
L2FLUSHDONE Output L2 hardware flush complete.
SMPEN[CN:0] Output Indicates whether a core is taking part in coherency.
DBGNOPWRDWN[CN:0] Output

Request not to power down the core:

0Do not request that the core stays powered-up.
1Request that the core stays powered-up.
DBGPWRUPREQ[CN:0] Output

Core power-up request:

0Do not request that the core is powered up.
1Request that the core is powered up.
DBGPWRDUP[CN:0] Input

Core powered up

0Core is powered down.
1Core is powered up.

Table A-9 Retention power management signals

Signal Direction Description
CPUQACTIVE[CN:0] Output Indicates whether the referenced core is active
CPUQREQn[CN:0] Input Indicates that the power controller is ready to enter or exit retention for the referenced core
CPUQDENY[CN:0] Output Indicates that the referenced core denies the power controller retention request
CPUQACCEPTn[CN:0] Output Indicates that the referenced core accepts the power controller retention request
NEONQACTIVE[CN:0] Output Indicates whether the referenced Advanced SIMD and Floating-point block is active
NEONQREQn[CN:0] Input Indicates that the power controller is ready to enter or exit retention for the referenced Advanced SIMD and Floating-point block
NEONQDENY[CN:0] Output Indicates that the referenced Advanced SIMD and Floating-point block denies the power controller retention request
NEONQACCEPTn[CN:0] Output Indicates that the referenced Advanced SIMD and Floating-point block accepts the power controller retention request
L2QACTIVE Output Indicates whether the L2 data RAMs are active
L2QREQn Input Indicates that the power controller is ready to enter or exit retention for the L2 data RAMs
L2QDENY Output Indicates that the L2 data RAMs deny the power controller retention request
L2QACCEPTn Output Indicates that the L2 data RAMs accept the power controller retention request
Non-ConfidentialPDF file icon PDF versionARM 100241_0001_00_en