3.3.158 odt_wr_control_31_00_next

Configures the ODT on and off settings for active and inactive ranks during writes. Access restrictions: RW Can be read from when in ALL states. Can be written to when in ALL states.

The odt_wr_control_31_00_next register characteristics are:

Usage constraints

There are no usage constraints.

Configurations

There is only one DMC configuration.

Attributes
Offset

0x360

Type

Read-write

Reset

0x08040201

Width

32