3.3.445 t_phyrdlat_now

Determines the maximum possible time between the assertion of the dfi_read_en signal, and the assertion of the dfi_rddata_valid signal by the PHY. Access restrictions: RO Can be read from when in ALL states. Cannot be written to and only updated when in CONFIG, LOW-POWER or PAUSED states.

The t_phyrdlat_now register characteristics are:

Usage constraints

There are no usage constraints.

Configurations

There is only one DMC configuration.

Attributes
Offset

0x1304

Type

Read-only

Reset

0x00000000

Width

32

Non-ConfidentialPDF file icon PDF versionARM 100568_0000_01_en
Copyright © 2016 ARM Limited or its affiliates. All rights reserved.