3.1 About this programmers model

The following information applies to the dmc620 registers:

  • The base address is not fixed, and can be different for any particular system implementation. The offset of each register from the base address is fixed.

  • Do not attempt to access reserved or unused address locations. Attempting to access these locations can result in Unpredictable behavior.

  • Unless otherwise stated in the accompanying text:

    • Do not modify undefined register bits.

    • Ignore undefined register bits on reads.

    • All register bits are reset to the reset value specified in the 3.3 Register summary

  • Access type is described as follows:

    RW

    Read and write.

    RO

    Read only.

    WO

    Write only.

Non-ConfidentialPDF file icon PDF version100568_0100_00_en
Copyright © 2016, 2017 Arm Limited (or its affiliates). All rights reserved.