3.3.117 t_rp_next

Configures the tRP timing parameter. This determines the delay applied after a PRECHARGE command before any other command is issued to the same bank. Access restrictions: RW Can be read from when in ALL states. Can be written to when in ALL states.

The t_rp_next register characteristics are:

Usage constraints

There are no usage constraints.

Configurations

There is only one DMC configuration.

Attributes
Offset

0x220

Type

Read-write

Reset

0x00000005

Width

32

Non-ConfidentialPDF file icon PDF version100568_0100_00_en