3.3.338 decode_control_now

Configures how the DRAM address is decoded from the system address. The DRAM address consists of the rank, cid, bank, row, and the column address. Note: Order fields must be unique, ie. row_order != bank_order != rank_order. Access restrictions: RO Can be read from when in ALL states. Cannot be written to and only updated when in CONFIG or LOW-POWER states.

The decode_control_now register characteristics are:

Usage constraints

There are no usage constraints.

Configurations

There is only one DMC configuration.

Attributes
Offset

0x1014

Type

Read-only

Reset

0x001A3000

Width

32