4.77 DP550 - trace

This section describes the trace sources.

ArchMsg.Error.IgnoredRead

Register read in reserved area. Fields:

NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.IgnoredWrite

Register write in reserved area. Fields:

DATA unsigned int
The data written to the address
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.ReadFromWriteOnlyRegister

Register read of write only register. Fields:

NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.ReadInReset

Register read during reset. Fields:

NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.UnsecureReadToSecureRegister

Non secure register read of secure register. Fields:

NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.UnsecureWriteoSecureRegister

Non secure register write of secure register. Fields:

DATA unsigned int
The data written to the address
NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.WriteInReset

Register write during reset. Fields:

DATA unsigned int
The data written to the address
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Error.WriteToReadOnlyRegister

Register write of read only register. Fields:

DATA unsigned int
The data written to the address
NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Access offset

ArchMsg.Info.Initialised

Initialised.

ArchMsg.Info.Processing

Processing layer. Fields:

STAGE string
The current processing stage

ArchMsg.Info.RegisterRead

Register read. Fields:

DATA unsigned int
The data returned by the component
NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Register access offset

ArchMsg.Info.RegisterWrite

Register write. Fields:

DATA unsigned int
The data written to the register
NAME string
Register name
NSECURE bool
True when the access is not a secure access
OFFSET unsigned int
Register access offset

ArchMsg.Info.Resetting

Resetting.

ArchMsg.Info.TimerFired

Timer has fired.

ArchMsg.Warn.DisplayLockFailed

Couldn't acquire display lock.

ArchMsg.Warning.FrameDropped

Frame tried to compose before the previous one finished. It will be dropped.

ArchMsg.Warning.clockTooHigh

The pixel clock is very high, it may affect model performance. Fields:

RATE unsigned int
Refresh rate
Non-ConfidentialPDF file icon PDF version100964_1180_00_en
Copyright © 2014–2019 Arm Limited or its affiliates. All rights reserved.