2.9 Q-Channels

The AXI5 to AHB5 bridge provides two Q-Channel interfaces. One Q-Channel is intended for clock control and the other Q-Channel for power control.

Both Q-Channels implement the low-power interfaces that the AMBA® Low Power Interface Specification, Arm® Q-Channel and P-Channel Interfaces describes.

The Q-Channels deny quiescent requests when there is ongoing activity or outstanding transfers. Incoming transactions are halted when the bridge is in quiescent state.

A synchronizer is always present on the pwr_qreqn input of the power Q-Channel. The presence of a synchronizer on the clk_qreqn input of the clock Q-Channel is configurable, by using the QCLK_SYNC_EN parameter.