| Home > Design for Test > Scan chain configurations | |||
ETM10 is a full-scan design comprising the following configuration options:
Controlled by SCANMUX6 and SCANMUX12.
Controlled by WMUX2.
The ETM10 internal scan chain concatenations are shown in Table 4.1.
Table 4.1. Internal scan chain concatenations
| Mode | Scan chains concatenated | ScanIn | ScanOut |
|---|---|---|---|
SCANMUX12 | 23, 11 | SCANIN[11] | ETM10SCANOUT[11] |
SCANMUX12 | 22, 10 | SCANIN[10] | ETM10SCANOUT[10] |
SCANMUX12 | 21, 9 | SCANIN[9] | ETM10SCANOUT[9] |
SCANMUX12 | 20, 8 | SCANIN[8] | ETM10SCANOUT[8] |
SCANMUX12 | 19, 7 | SCANIN[7] | ETM10SCANOUT[7] |
SCANMUX12 | 18, 6 | SCANIN[6] | ETM10SCANOUT[6] |
SCANMUX12 | 17, 5 | SCANIN[5] | ETM10SCANOUT[5] |
SCANMUX12 | 16, 4 | SCANIN[4] | ETM10SCANOUT[4] |
SCANMUX12 | 15, 3 | SCANIN[3] | ETM10SCANOUT[3] |
SCANMUX12 | 14, 2 | SCANIN[2] | ETM10SCANOUT[2] |
SCANMUX12 | 13, 1 | SCANIN[1] | ETM10SCANOUT[1] |
SCANMUX12 | 12, 0 | SCANIN[0] | ETM10SCANOUT[0] |
SCANMUX6 | 23, 11, 17, 5 | SCANIN[5] | ETM10SCANOUT[5] |
SCANMUX6 | 22, 10, 16, 4 | SCANIN[4] | ETM10SCANOUT[4] |
SCANMUX6 | 21, 9, 15, 3 | SCANIN[3] | ETM10SCANOUT[3] |
SCANMUX6 | 20, 8, 14, 2 | SCANIN[2] | ETM10SCANOUT[2] |
SCANMUX6 | 19, 7, 13, 1 | SCANIN[1] | ETM10SCANOUT[1] |
SCANMUX6 | 18, 6, 12, 0 | SCANIN[0] | ETM10SCANOUT[0] |
The internal scan chains do not cross clock domains during 6, 12, or 24 scan chain modes.
For scan testing of the core, you must tie the SCANMUX12, SCANMUX6, and WMUX2 signals in one of the configurations listed in Table 4.2.
Table 4.2. Scan chain configurations
| Configuration | Pins | Maximum chain length |
|---|---|---|
24 internal scan chains | SCANMUX12 LOWSCANMUX6 LOW | 237 |
12 internal scan chains | SCANMUX12 HIGHSCANMUX6 LOW | 465 |
6 internal scan chains | SCANMUX12 LOWSCANMUX6 HIGH | 921 |
Restricted | SCANMUX12 HIGHSCANMUX6 HIGH | - |
2 wrapper scan chains | WMUX2 HIGH | 155 |
1 wrapper scan chain | WMUX2 LOW | 292 |