The prescaler generates a timer clock enable that is used to enable the decrementing of the timer counter at one of the following rates:
the effective timer clock rate where TIMCLK is qualified by TIMCLKENX
the effective timer clock rate divided by 16
the effective timer clock rate divided by 256.
Figure 2.6 shows how the timer clock enable is generated by the prescaler.
Figure 2.7 shows an example of how the prescaler generates the timer clock enable for a prescaler setting of divide by 16.