17.3. ETM ATB and CTI interfaces

Table 17.3 shows the setup and hold times for:

Table 17.3. Timing parameters of ETM ATB and CTI interfaces

SignalClockSetup parameterPercent of clock periodHold parameterPercent of clock period
AFREADYMATCLKTovafreadym30%Tohafreadym10%
AFVALIDMATCLKTisafvalidm30%Tihafvalidm10%
ASICCTL[7:0]CLKTovasicctl30%Tohasicctl10%
ATRESETnATCLK[1]Tisatresetn50%Tihatresetn10%
ATCLKENATCLKTisatclken30%Tihatclken10%
ATREADYMATCLKTisatreadym30%Tihatreadym10%
ATBYTESM[1:0]ATCLKTovatbytesm30%Tohatbytesm10%
ATDATAM[31:0]ATCLKTovatdatam30%Tohatdatam10%
ATIDM[6:0]ATCLKTovatidm30%Tohatidm10%
ATVALIDMATCLKTovatvalidm30%Tohatvalidm10%
TRIGGERATCLKTovtrigger30%Tohtrigger10%
CTICHOUT[3:0]ATCLKTovctichout30%Tohctichout10%
CTICHIN[3:0]ATCLKTisctichin30%Tihctichin10%
nCTIIRQCLK[2]Tovnctiirq30%Tohnctiirq10%

[1] This signal has multiple end-points and must be level-sensitive.

[2] This signal has multiple end-points and must be treated as level-sensitive.

Copyright © 2006 ARM Limited. All rights reserved.ARM DDI 0344B
Non-Confidential