3.2.45. c9, Overflow Flag Status Register

The purpose of the Overflow Flag Status (FLAG) Register is to enable or disable any of the performance monitor counters producing an overflow flag.

When reading this register, any overflow flag that reads as 0 indicates the counter has not overflowed. Any overflow flag that reads as 1 indicates the counter has overflowed.

When writing this register, any overflow flag written with a value of 0 is ignored, that is, not updated. Any overflow flag written with a value of 1 clears the counter overflow flag to 0.

The FLAG Register is:

Figure 3.41 shows the bit arrangement of the FLAG Register.

Figure 3.41. Overflow Flag Status Register format


Table 3.88 shows how the bit values correspond with the FLAG Register functions.

Table 3.88. Overflow Flag Status Register bit functions

BitsFieldFunction

[31]

C

Cycle counter overflow flag.

[30:4]

-

Reserved. UNP, SBZP.

[3]

P3

Counter 3 overflow flag.

[2]

P2

Counter 2 overflow flag.

[1]

P1

Counter 1 overflow flag.

[0]

P0

Counter 0 overflow flag.


Table 3.89 shows the results of attempted access for each mode.

Table 3.89. Results of access to the Overflow Flag Status Register[36]

 

Secure privileged

Nonsecure privileged

Secure User

Nonsecure User

EN[1]ReadWriteReadWriteReadWriteReadWrite
0

Data

Data

Data

Data

Undefined

Undefined

Undefined

Undefined

1

Data

Data

Data

Data

Data

Data

Data

Data

[36] An entry of Undefined in the table means that the access gives an Undefined Instruction exception when the coprocessor instruction is executed.

[1] The EN bit in c9, User Enable Register enables User mode access of the Performance Monitor Registers.


To access the FLAG Register, read or write CP15 with:

MRC p15, 0, <Rd>, c9, c12, 3 ; Read FLAG Register
MCR p15, 0, <Rd>, c9, c12, 3 ; Write FLAG Register