| Home > Signal Descriptions > Non-AXI signals | |||
Table A.1 lists signals that are present on the ACI but are not described in the AMBA AXI Protocol Specification.
Table A.1. Non-standard signals
| Name | Type | Source | Description |
|---|---|---|---|
| REMAP | Input | Remap controller | This changes the memory map from that required during boot-up to that for normal operation: 0 = Remap memory alias or move is not active 1 = Remap memory alias or move is active. See Memory map. |
| TZPROT | Input | Security controller[1][2] | Protection indicator for master interfaces: 0 = secure 1 = non-secure. See TrustZone support. |
[1] You can tie this signal off at the interconnect for a static configuration. [2] This component is available from ARM Limited. See the PrimeCell Infrastructure AMBA 3 TrustZone Protection Controller (BP147) Technical Overview for more information. | |||