| Home > Programmer’s Model for Test > Integration test registers > Integration Inputs Register | |||
The read-only int_inputs Register enables an external master to access the inputs of the SMC using the APB interface. This register is only for test. You cannot read this register in the Reset state.
Figure 4.3 shows the register bit assignments.
Table 4.3 lists the register bit assignments.
Table 4.3. Int_inputs Register bit assignments
| Bits | Name | Function |
|---|---|---|
| [31:10] | - | Read undefined |
| [9] | msync1 | Returns the value of this top-level tie-off |
| [8] | async1 | Returns the value of this top-level tie-off |
| [7] | ebibackoff1 | Returns the value of ebibackoff1 |
| [6] | ebignt1 | Returns the value of ebigrant1 |
| [5] | msync0 | Returns the value of this top-level tie-off |
| [4] | async0 | Returns the value of this top-level tie-off |
| [3] | ebibackoff0 | Returns the value of ebibackoff0 |
| [2] | ebignt0 | Returns the value of ebigrant0 |
| [1] | use_ebi | Returns the value of use_ebi |
| [0] | csysreq | Returns the value of csysreq |