4.1.2. Integration Inputs Register

The read-only int_inputs Register enables an external master to access the inputs of the SMC using the APB interface. This register is only for test. You cannot read this register in the Reset state.

Figure 4.3 shows the register bit assignments.

Figure 4.3. Int_inputs Register bit assignments

Table 4.3 lists the register bit assignments.

Table 4.3. Int_inputs Register bit assignments

BitsNameFunction
[31:10]-Read undefined
[9]msync1Returns the value of this top-level tie-off
[8]async1Returns the value of this top-level tie-off
[7]ebibackoff1Returns the value of ebibackoff1
[6]ebignt1Returns the value of ebigrant1
[5]msync0Returns the value of this top-level tie-off
[4]async0Returns the value of this top-level tie-off
[3]ebibackoff0Returns the value of ebibackoff0
[2]ebignt0Returns the value of ebigrant0
[1]use_ebiReturns the value of use_ebi
[0]csysreqReturns the value of csysreq
Copyright © 2005-2007 ARM Limited. All rights reserved.ARM DDI 0380F