2.3.1. Synchronous clocking

The Cortex-A9 uniprocessor has one functional clock input, CLK.

The Cortex-A9 uniprocessor does not have any asynchronous interfaces. All the bus interfaces and the interrupt signals must be synchronous with reference to CLK.

The AXI bus clock domain can be run at n:1 (AXI: processor ratio to CLK) using the ACLKEN signal.

Figure 2.3 shows a timing example with ACKLENM0 used with a 3:1 clock ratio between CLK and ACLK in a Cortex-A9 uniprocessor.

Figure 2.3. ACLKENM0 used with a 3:1 clock ratio

To view this graphic, your browser must support the SVG format. Either install a browser with native support, or install an appropriate plugin such as Adobe SVG Viewer.


The master port, Master0, changes the AXI outputs only on the CLK rising edge when ACLKENM0 is HIGH.

Copyright © 2008-2012 ARM. All rights reserved.ARM DDI 0388H