2.5.38. TAPOp_SetLogging

Switches debug logging for TAPOp functions on or off, for a particular TAP controller.

Syntax

#include “tapop.h”

extern TAPOp_Error TAPOp_SetLogging(unsigned8 connectId, unsigned32 flags);

where:

connectId

Connection ID, as returned by TAPOp_OpenConnection.

flags

If 0, switch logging off, otherwise switch it on.

Return

The function returns:

TAPOp_NoError

No error.

TAPOp_NoSuchConnection

The connectId was not recognized.

TAPOp_RPC_Connection_Fail

The RPC connection was lost while processing thisrequest.

TAPOp_CannotEnableLogging

The server could not enable logging.

Usage

This call does not require a selected connection to a TAP controller. It changes the level of debugging output and returns.

See also

These TAPOp API functions provide similar or related functionality:

Copyright © 1998-2002 ARM Limited. All rights reserved.ARM DUI 0154B