Forces an order for target connection on a multiprocessor development platform, regardless of the target you use to initiate a connection. This enables pre-setup of specific targets to guarantee correct operation, such as initializations. If a listed target is already connected, then no attempt is made to re-connect to that target.
For each target you want to pre-connect:
Specify the full connection name for the target (that is, the name as it appears in the Connect to Target window.
Press Enter to complete the entry.
A new Pre_Connect entry is created for
the target.
For example, *Pre_Connect ARM940T_0.
The targets are listed in reverse order. Therefore, the last target you enter is connected first. You can re-order this list if required.