| Home > Setting up the Trace Software > CoreSight ETB and RealView ICE > Configuring your CoreSight development platform | |||
To configure your CoreSight development platform to capture trace in the CoreSight ETB:
Install RealView ICE and connect up the hardware as described in the chapter.
The RealView Trace software is included with RealView Debugger, and does not require a separate installation.
Select Start → Programs → ARM → RealView Development Suite v4.0 → RealView Debugger v4.0 to start RealView Debugger.
Configure RealView ICE to identify the processors and CoreSight components on your development platform. You must also configure RealView ICE to access the CoreSight ECT.
Select Registers from the View menu to display the Registers view.
If your development platform has multiple trace sources, then you must configure the CoreSight Trace Funnel to identify the source from which trace is to be captured:
Connect to the CSTFunnel_ target.n
Set up the Trace Funnel registers.
If your development platform contains multiple processors and multiple ETMs, only one CoreSight ETM at a time can be chosen as the trace source in this release.
Configure the CoreSight ETB registers:
Connect to the CSETB_ target.n
Set up the CSETB registers. Figure B.5 shows an example.
Connect to the target processor on your development platform.
Connect to the TPA.
RealView ICE and RealView Trace User Guide
the following in the RealView Debugger User Guide:
Creating a Debug Configuration on page 3‑10
Connecting to a target on page 3‑19.