Home > Signal Descriptions > DVI display interface |
The digital CLCD data from the Northbridge is passed to a T.M.D.S. transmitter to provide the DVI digital data and to a triple video DAC to provide the analogue RGB signals. The DDC2B interface is provided by a custom Two-wire Interface (SBCon) implemented in the Southbridge.
The DVI combined connector (J16) is positioned on the rear panel of the enclosure. See Figure 3.3 for the location of the connector.
The mechanical interconnect includes 29 signal contacts, that are divided into two sections. The first section is organized as three rows of eight contacts. The second section contains five signals that are designed specifically for analog video signals. Hoizontal Sync, Vertical Sync, R, G, and B are all required for analog implementations.
A fused (1A anti-surge) +5V supply (pin 14) is provided by the PB-A8.
The combined DVI connector is shown in Figure A.13.
The DVI connector signals are listed in Table A.9.
Table A.9. DVI connector signals
Pin | Signal | Pin | Signal | Pin | Signal |
---|---|---|---|---|---|
1 | T.M.D.S. Data2- | 9 | T.M.D.S. Data1- | 17 | T.M.D.S. Data0- |
2 | T.M.D.S. Data2+ | 10 | T.M.D.S. Data1+ | 18 | T.M.D.S. Data0+ |
3 | T.M.D.S. Data2/4 Shield | 11 | T.M.D.S. Data1/3 Shield | 19 | T.M.D.S. Data0/5 Shield |
4 | T.M.D.S. Data4- | 12 | T.M.D.S. Data3- | 20 | T.M.D.S. Data5- |
5 | T.M.D.S. Data4+ | 13 | T.M.D.S. Data3+ | 21 | T.M.D.S. Data5+ |
6 | DDC Clock | 14 | +5V Power | 22 | T.M.D.S. Clock Shield |
7 | DDC Data | 15 | Ground (for +5V) | 23 | T.M.D.S. Clock+ |
8 | Analog Vertical sync | 16 | Hot Plug Detect | 24 | T.M.D.S. Clock- |
C1 | Analog Red | C2 | Analog Green | C3 | Analog Blue |
C4 | Analog Horizontal Sync | C5 | Analog Ground (analog R, G, and B return) |
The PB-A8 implements a single link, T.M.D.S. Data 3, 4, and 5 connections are not used.