| Home > Versatile Express Model: Platform and Components > VE_SysRegs component > Parameters | |||
Table 6.11 provides a description of the configuration parameters for the VE_SysRegs component.
Table 6.11. VE_SysRegs configuration parameters
| Parameter name | Description | Type | Allowed value | Default value |
|---|---|---|---|---|
boot_switches_Value | boot select switch | integer | as switch S8 on VE hardware[a] | 0 |
clcdid | color LCD ID | integer | - | 0x1 |
proc_id_tile_site1 | processor ID register | integer | - | 0x04000000 |
proc_id_tile_site2 | processor ID register | integer | - | 0x04000000 |
sys_id | system identification register | integer | - | 0x01400400 |
tile1 | tile 1 fitted | boolean | true/false | true |
tile2 | tile 2 fitted | boolean | true/false | false |
user_switches_value | user switches | integer | as switch S6 on VE hardware[a] | 0 |
[a] Full details on switch values and their effects are provided elsewhere. See the RealView Development Suite Real-Time System Models User Guide. | ||||