ARM Technical Support Knowledge Articles

ERROR L235 (USE RTX-251 CONTROL)

Applies to: L251 Linker/Locator

Answer


Information in this article applies to:


QUESTION

During linking, I receive the following error message:

*** FATAL ERROR L235: USE RTX-251 CONTROL.

What is wrong and how do I fix this problem?

ANSWER

Your application uses the _task_ keyword to define RTX tasks. Therefore, you must specify the RTX real-time operating system that you are using.

In uVision2, you may specify this in the dialog Options for Target - Target - Operating System. If you use the tools at the command-line level, use the linker directives RTX251.

Article last edited on: 2004-05-10 15:33:05

Rate this article

[Bad]
|
|
[Good]
Disagree? Move your mouse over the bar and click

Did you find this article helpful? Yes No

How can we improve this article?

Link to this article
Copyright © 2011 ARM Limited. All rights reserved. External (Open), Non-Confidential