ARM Technical Support Knowledge Articles

KEIL APPLICATION NOTE 162 ERRATA FOR FX FAMILY

Applies to: General Topics

Answer


Information in this article applies to:


QUESTION

I am using Keil Application note 162 and the EZ USB FX board. I go to down load the Monitor for the default Cypress EZ USB FX2 evaluation connection. I set the communications port COM1 (matches my PC com port) and the baud rate 19200 but the target will not connect. What is the solution?

ANSWER

Application Note 162 has not been updated for the FX family chips. The proper baud rate should be 38400.

Article last edited on: 2004-04-19 21:46:35

Rate this article

[Bad]
|
|
[Good]
Disagree? Move your mouse over the bar and click

Did you find this article helpful? Yes No

How can we improve this article?

Link to this article
Copyright © 2011 ARM Limited. All rights reserved. External (Open), Non-Confidential