ARM Technical Support Knowledge Articles

I/O ERROR ON WORK FILE

Applies to: General Topics

Answer


Information in this article applies to:


QUESTION

While building my application, I receive the following Linker Error:

***  FATAL ERROR L213: I/O ERROR ON WORK FILE:
     EXCEPTION 0029H: ACCESS TO FILE DENIED

What is the reason for this error?

ANSWER

The Keil development tools create work files in the standard Windows work file folder. The path to the folder is specified by the TEMP environment variable. If you receive this error message, the TEMP folder may not exist or the environment path may be set incorrectly.

You may check the path setting at the command prompt (DOS box) by typing the command SET to list all environment variables.

Under Windows NT/2000/XP, environment variables are configured by My Computer - Properties (opens on right mouse click from the context menu). Then, open Advanced - Environment Variables. Under User Variables, check the setting of the variable TEMP. The path must refer to an existing folder on your computer with full access permissions.

Article last edited on: 2005-05-02 11:20:21

Rate this article

[Bad]
|
|
[Good]
Disagree? Move your mouse over the bar and click

Did you find this article helpful? Yes No

How can we improve this article?

Link to this article