Applies to: ULINK USB-JTAG Debugger
Information in this knowledgebase article applies to:
Attempting to connect to an MCB1000 board with ULINK2 or ULINK-ME returns the following message:
SWD communication failure
in Options for Target Debug Settings.
This can happen when you mistakenly program the security bits on the LPC11xx device.
Download FlashMagic from Embedded Systems Academy, and under ISP Erase flash make sure to check Erase all Flash+Code Rd Prot checkbox.
Then click the Erase button to erase the device. Once the security bits are reset, ULINK2 will connect normally.
Request the files attached to this knowledgebase article.