Answer

Hazard detection needs to be done on the entire "container" of the transfer as defined by ADDR, SIZE, BURST and LEN. Overlapping locations need to be dealt with appropriately if forwarding is used. For the simpler schemes, i.e. stalling until earlier transfers have completed, partially overlapping and fully overlapping transactions can be treated the same.