ARM Technical Support Knowledge Articles

WARNING 7 (MODULE NAME NOT UNIQUE)

Applies to: BL51 Code-banking Linker/Locator

Answer


Information in this article applies to:


SYMPTOMS

When I build my project, I get the following warning from the linker:

WARNING L7: MODULE NAME NOT UNIQUE
MODULE: C:TESTISR.OBJ (ISR)

How do I resolve this?

CAUSE

This is commonly caused by more than one source file generating the ISR.OBJ file. For example, if you have ISR.C and ISR.A51 in your project, they will both compile/assemble to produce ISR.OBJ. The linker requires an object file for each source file, so it generates the warning.

RESOLUTION

Rename your source files so the name before the extension (in this case 'ISR') is unique for each source file. Remove and re-add the source files to your project.

MORE INFORMATION

Article last edited on: 2005-07-19 15:21:33

Rate this article

[Bad]
|
|
[Good]
Disagree? Move your mouse over the bar and click

Did you find this article helpful? Yes No

How can we improve this article?

Link to this article
Copyright © 2011 ARM Limited. All rights reserved. External (Open), Non-Confidential