EXPECTED DELIMITER ')' AFTER ARGUMENT (INCDIR)

Applies to: A51 Macro Assembler

Answer


Information in this article applies to:


QUESTION

I invoke the A51 assembler using the following command line:

A51 ASAMPLE.A51 PRINT(ASAMPLE.LST) INCDIR(H1;H2)

and I get:

A51 FATAL ERROR -
  LINE:       C:C51BINA51.EXE ASAMPLE1.A51 PRINT(ASAMPLE1.LST) INCDIR(H1#
  ERROR:      EXPECTED DELIMITER ')' AFTER ARGUMENT
A51 TERMINATED.

Why?

ANSWER

The A51 manual has a mistake on the page where the INCDIR directive is explained. It states that include paths should be separated by a semicolon. The correct way is to separate paths using a comma.

Change your command line to:

A51 ASAMPLE.A51 PRINT(ASAMPLE.LST) INCDIR(H1,H2)